The push button “LISTEN” control switch should only be depressed
after the ground microphone has been rmly placed on a solid surface
and one to two seconds Sensor Settle Time elapsed. When using the
direct contact microphone, be certain that the tip is in rm contact with
the pipe, valve box, etc., before depressing the “LISTEN” control
switch.
B. Ground Microphone (Part No. 2916427)
(Figure 4)
1. General Specications:
Construction: Acoustically suspended variable
reluctance sensor
Impedance: 380 Ohm DC resistance
Frequency
Response: 10 - 300 Hertz
Weight: Approximately 2 Lbs. 5 Oz.
(1049 grams)
7