Heath-consultants Heath Volume Corrector (HVC) Instrukcja Użytkownika Strona 4

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 3
4
Heath Volume Corrector (HVC) Overview
The HVC 325 is a microprocessor based, self-contained system designed for the purpose of performing
ideal gas law calculations using integral pressure, temperature and volume sensing devices.
HVC Features
Intrinsically safe: Class I Div I Group D (without internal modem)
Single Alkaline “D” battery provides power for up to 4 years
Single Lithium “AA” Backup battery will provide 100% operation for up to 1 year after main
battery is depleted
Measures & records pressure and temperature sensors every meter revolution or every min
(programmable)
Continuous LCD defaults to Corrected Volume. Scrolling allows Uncorrected Volume, Pressure,
Gas Temperature, Correction Factor, Main and Lithium Battery Voltage, as well as any active
Alarm to be displayed.
Non-volatile Flash memory saves Calibration, Transducer Coefficients Configuration & Site info
if all power is lost
Profiler data recording- Circular log: 130 days/hourly: Time/ Corrected/ Uncorrected/ Ave
Pressure/ Ave Gas Temperature
Event Log (Records alarms & configuration changes)
System Alarms (H/L Press, H/L Temp, main and lithium backup battery)
Contract Usage Alarms (High Day/ Warning Month/ High Month)
Contract Management (Nomination/ Allocation)
All alarms can be reset via scroll button (No laptop needed)
Call out upon alarm
Remote Communications Ready (External Direct port & Internal Remote RS232’s)
Multi-Drop to several instruments from one modem (Up to 62)
Previous Month Total Volumes (Uncor & Corr) can be displayed on LCD
Max Day Volume “total” & Date stamp of Max Day can be displayed on LCD (Max Day can be
reset via scroll button)
Protocols included: Sandia (Native)/ Modbus RTU or ASCII
Pulse Outputs (Uncorrected & Corrected)
Units of measure (PSIA, KPA, BAR Deg. F/ Deg. C)
Reliable Falling magnet/ Reed switch input
Index uses all brass miter gears that are easily reversible for CW & CCW meter direction
HVC Firmware can be upgraded via PC
IP64, Aluminum, Powder coated paint over chromate surface prep, lockable stainless steel hasp
closure (Saltwater spray tested)
HVC Host software will also operate the LVC and XVC devices
HVC Host software is very user friendly
HVC Host is compatible with Windows 7, Win Vista and Win XP