Przeglądanie stron 131
12-8
USER HANDBOOK
FILTER HOUSING
ADAPTOR
FILTER DISC
(
Part No. 67199
)
PENCIL
(OR SIMILAR)
Fig. 12.7 Adaptor Filter Removal
CAUTION The contents of this filter must only be
replenished with GMI recommended Silica Gel
7) Using GMI recommended silica gel (Part No.67205),
fill the filter housing to a level just below the internal
threads. Do not overfill, otherwise the adaptor
cannot be assembled.
8) Attach filter adaptor to filter housing, in a clockwise
direction, then tighten to secure. See Fig. 12.5.
Note: Care must be taken not to overtighten the
adaptor.
9) Before attaching the filter housing to the filter bulb,
check the washer for signs of damage. If
damaged, it must be replaced with a new washer
(Part No.12379).