Heath-consultants Odorator Instrukcja Użytkownika Strona 23

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 31
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 22
Appendix C
The reading as a percentage between the adjacent chart readings can be
used to determine the actual value using the same percentage between
chart actuals.
The reading of .23 is 30% of the difference in the chart higher reading from
the chart lower reading. The lower chart reading and actual will be used as
the base or reference.
.23 - .20
= .3 or 30%
.30 - .20
Therefore the actual value will be 30% of the difference in the chart higher
actual from the chart lower actual. Again, the lower value will be the base
or reference.
30% of (.28 - .19) = .3 x .09 = .027 which is rounded off to .03
Since the actual value base is .19, the actual value will be .19 + .03 = .22% gas.
Interpolation Example 2: DOWN Column
An ODORATOR reading of .23 is taken at 2700’. The calibration elevation is
5500’ so the elevation difference is 2700-5500 = -2800 which is rounded of to
-3000’. The difference is negative so the DOWN 3000 correction column will
be used.
A reading of .23 lies between chart readings of .20 and .30. This reading
also lies between actual values of .15 and .22 using the DOWN 3000 cor-
rection column.
The reading as a percentage between the adjacent chart readings can be
used to determine the actual value using the same percentge between chart
actuals.
The reading of .23 is 30% of the difference in the chart higher reading from
the chart lower reading. The lower chart reading and actual will be used as
the base or reference.
.23 - .20
= .3 or 30%
.30 - .20
14
Przeglądanie stron 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 29 30 31

Komentarze do niniejszej Instrukcji

Brak uwag